Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
2.490 inches
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.060 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.150 inches
Mounting Surface To Terminal End Distance:
2.475 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Ultimate Trip Time Per Pole In Seconds:
6.000 all locations and 60.000 all locations
Ultimate Trip Time Per Pole In Seconds:
6.000 and 60.000 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
1 control
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
3.5 millimeters
Thread Pitch In Millimeters:
Any acceptable
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
6.000 at 150 pct all locations and 60.000 at 150 pct all locations and 0.400 at 400 pct all locations and 1.500 at 400 pct all locations
Trip Delay Time In Seconds Per Rated Continuous Current:
6.000 at 150 pct and 60.000 at 150 pct and 0.400 at 400 pct and 1.500 at 400 pct all locations
Switch Terminal Type:
Turret
Switch Current Rating And Type In Amps:
10.0 ac
Switch Voltage Rating And Type In Volts:
250.0 ac
Thread Tolerance Class:
Any acceptable
Frequency In Hertz:
400.0 all locations
Unpackaged Unit Weight:
7.400 ounces
Thread Series Designator:
Iso s
Terminal Type And Quantity:
4 threaded stud
Item Name:
Breaker,individual
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC